MOXA EDS-510A Series

SPHINX in Europa
AT
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Produktgruppen > Ethernet Switches > MOXA EDS-510A Series

MOXA EDS-510A Series

Industrial 7+3G-Port Gigabit Managed Ethernet Switch

MOXA EDS-510A Series
1602_26832.png
1602_26833.png
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • 2 Gigabit Ethernet ports for Redundant Ring and 1 Gigabit Ethernet port for Uplink solution
  • Turbo Ring (Recovery time < 20 ms), RSTP/STP (IEEE802.1W/D) for Ethernet redundancy
  • QoS, IGMP snooping/GMRP, VLAN, LACP, SNMP V1/V2c/V3, RMON supported
  • IEEE802.1X and https/SSL enhance network security
  • ABC-01 (Automatic Backup Configurator) for system configuration backup

Der redundante Managed Gigabit-Ethernet-Switch EDS-510A verfügt über bis zu drei Gigabit-Ethernet-Ports und eignet sich damit für den Aufbau eines Gigabit-Turbo Rings, bei dem ein Gigabit-Port für Uplinks übrig bleibt. Der redundante Ethernet-Turbo Ring (Wiederherstellungszeit < 20 ms) und RSTP/STP (IEEE 802.1w/D) können die Systemzuverlässigkeit und die Verfügbarkeit Ihres Netzwerk-Backbone steigern. Die EDS-510A-Serie wurde speziell für Anwendungen mit hohen Kommunikationsanforderungen entwickelt, darunter Prozesssteuerung, Schiffbau, ITS- und DCS-Systeme, die von einem skalierbaren Backbone profitieren.

ProdGrafik

Features:

  • 2 Gigabit Ethernet Ports for Redundant Ethernet Ring and 1 Gigabit Ethernet Port for Uplink
  • IGMP Snooping and GMRP for filtering multicast traffic from industrial Ethernet Protocols
  • Port-based IEEE802.1Q VLAN and GVRP protocol to ease network planning
  • QoS-IEEE802.1p/1Q and TOS/DiffServ to increase determinism
  • 802.3ad, LACP for optimum bandwidth utilization
  • IEEE802.1X and https/SSL to enhance network security
  • SNMP V1/V2c/V3 for different levels of network management
  • RMON for efficient network monitoring and proactive capability
  • Bandwidth management prevents unpredictable network status
  • ABC-01 (Automatic Backup Configurator) for system configuration backup
  • Port Lock for access from unauthorized MAC address
  • Port mirroring for online debugging
  • Automatic warning by exception through email, relay output
  • Digital inputs to integrate sensors and alarms with IP networks
  • Automatic recovery of connected device’s IP addresses
  • Line-swap fast recovery (Patented)
  • Regular (0 to 60°C) and extended (-40 to 75°C) operating temperature models available
  • IP30, rugged high-strength case
  • Long-haul transmit distance of 40 km or 80 km
  • DIN-Rail or panel mounting ability
  • Configurable by Web browser, Telnet/Serial console, Windows utility
  • Ping commands to identify network segment integrity
  • Redundant 12-45 VDC power inputs and over current protection





Technology

Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseX
IEEE 802.3x for Flow Control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP

Protocols
IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, Syslog, DHCP Option 66/67/82, SSH, SNMP Inform, EtherNet/IP, Modbus/TCP, LLDP, IEEE 1588 PTPv2, IPv6, NTP Server/Client

MIB
MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9

Flow Control
IEEE 802.3x flow control, back pressure flow control


Switch Properties

Priority Queues
4

Max. Number of Available VLANs
64

VLAN ID Range
VID 1 to 4094

IGMP Groups
256

MAC Table Size
8 K

Packet Buffer Size
1 Mbit


Interface

Fiber Ports
1000BaseSFP slot

RJ45 Ports
10/100BaseT(X) or 10/100/1000BaseT(X) auto negotiation speed

Console Port
RS-232 (RJ45 connector)

DIP Switches
Turbo Ring, Master, Coupler, Reserve

LED Indicators
PWR1, PWR2, FAULT, 10/100M (TP port), 1000M (Gigabit port), MSTR/HEAD, CPLR/TAIL

Alarm Contact
2 relay outputs with current carrying capacity of 1 A @ 24 VDC

Digital Inputs
2 inputs with the same ground, but electrically isolated from the electronics.
  • +13 to +30V for state “1”
  • -30 to +3V for state “0”
  • Max. input current: 8 mA

Power Requirements

Input Voltage
24 VDC (12 to 45 VDC), redundant dual inputs

Input Current
EDS-510A-3GT: 0.65 A @ 24 V
EDS-510A-1GT2SFP: 0.44 A @ 24 V
EDS-510A-3SFP: 0.46 A @ 24 V

Overload Current Protection
Present

Connection
2 removable 6-contact terminal blocks

Reverse Polarity Protection
Present


Physical Characteristics

Housing
Metal, IP30 protection

Dimensions
80.2 x 135 x 105 mm (3.16 x 5.31 x 4.13 in)

Weight
1170 g

Installation
DIN-rail mounting, wall mounting (with optional kit)


Environmental Limits

Operating Temperature
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature
-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
5 to 95% (non-condensing)

Standards and Certifications

Safety
UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1

Hazardous Location
UL/cUL Class I Division 2 Groups A/B/C/D, ATEX
Zone 2 Ex nC IIC

EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A

EMS
EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3,
EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8

Marine
DNV, GL

Traffic Control
NEMA TS2

Shock
IEC 60068-2-27

Freefall
IEC 60068-2-32

Vibration
IEC 60068-2-6


MTBF (mean time between failures)

Time
204,000 hrs

Database
MIL-HDBK-217J, GB 25°C


Ordering Information

EDS-510A-1GT2SFP Managed Gigabit Ethernet switch with 7 10/100BaseT(X) ports, 1 10/100/1000BaseT(X) port, and 2 SFP slots for adding SFP-1G series Gigabit Ethernet modules, 0 to 60°C operating temperature
EDS-510A-1GT2SFP-T Managed Gigabit Ethernet switch with 7 10/100BaseT(X) ports, 1 10/100/1000BaseT(X) port, and 2 SFP slots for adding SFP-1G series Gigabit Ethernet modules, -40 to 75°C operating temperature
EDS-510A-3GT Managed Gigabit Ethernet switch with 7 10/100BaseT(X) ports, and 3 10/100/1000BaseT(X) ports, 0 to 60°C operating temperature
EDS-510A-3GT-T Managed Gigabit Ethernet switch with 7 10/100BaseT(X) ports, and 3 10/100/1000BaseT(X) ports, -40 to 75°C operating temperature
EDS-510A-3SFP Managed Gigabit Ethernet switch with 7 10/100BaseT(X) ports, and 3 SFP slots for adding SFP-1G series Gigabit Ethernet modules, 0 to 60°C operating temperature
EDS-510A-3SFP-T Managed Gigabit Ethernet switch with 7 10/100BaseT(X) ports, and 3 SFP slots for adding SFP-1G series Gigabit Ethernet modules, -40 to 75°C operating temperature





Recommended Software and Accessories
ABC-01 RS-232 RJ45-based Automatic Backup Configurator
EDS-SNMP OPC Server Pro
DR series DIN-Rail 24 VDC power supplies

Ordering Information SFP Modules
Available Models Port Interface
Standard
Temperature
(-40 to 85°C)
Wide
Temperature
(0 to 60°C)
1000BaseSX, LC Connector, 0.5 km 1000BaseLSX, LC Connector, 2 km 1000BaseLX, LC Connector, 10 km 1000BaseLH, LC Connector, 30 km 1000BaseLHX, LC Connector, 40 km 1000BaseZX, LC Connector, 80 km 1000BaseEZX, LC Connector, 100 km
SFP-1GSXLC SFP-1GSXLC-T∗ 1 --- --- --- --- --- ---
SFP-1GLSXLC SFP-1GLSXLC-T --- 1 --- --- --- --- ---
SFP-1GLXLC SFP-1GLXLC-T --- --- 1 --- --- --- ---
SFP-1GLHLC SFP-1GLHLC-T --- --- --- 1 --- --- ---
SFP-1GLHXLC SFP-1GLHXLC-T --- --- --- --- 1 --- ---
SFP-1GZXLC SFP-1GZXLC-T --- --- --- --- --- 1 ---
SFP-1GEZXLC --- --- --- --- --- --- --- 1


∗Note: SFP-1GSXLC-T: -20 to 75°C operating temperature

Ordering Information WDM-type (BiDi) SFP Modules
Available Models Port Interface
Standard Temperature
(0 to 60°C)
Wide Temperature (-40 to 85°C) 1100BaseSFP, LC Connector, 11 km 1100BaseSFP, LC Connector, 20 km 1100BaseSFP, LC Connector, 40 km
TX 1311 nm,
RX 1550 nm
TX 1550 nm,
RX 1311 nm
TX 1311 nm,
RX 1550 nm
TX 1550 nm,
RX 1311 nm
TX 1311 nm,
RX 1550 nm
TX 1550 nm,
RX 1311 nm
SFP-1G11ALC SFP-1G11ALC-T 1 --- --- --- --- ---
SFP-1G11BLC SFP-1G11BLC-T --- 1 --- --- --- ---
SFP-1G20ALC SFP-1G20ALC-T --- --- 1 --- --- ---
SFP-1G20BLC SFP-1G20BLC-T --- --- --- 1 --- ---
SFP-1G40ALC SFP-1G40ALC-T --- --- --- --- 1 ---
SFP-1G40BLC SFP-1G40BLC-T --- --- --- --- --- 1


Kunden, die diesen Artikel gesehen haben, sahen auch
Alle Cookies akzeptieren Ablehnen Konfigurieren

Diese Website verwendet Cookies, um eine bestmögliche Erfahrung bieten zu können. Mehr erfahren.